Nanoscale Electric Air Decontamination

Genano Nanoparticle Air Purification Systems

Clinical-Grade Air Decontamination for High-Hygiene Environments • Capturing Ultrafine Bio-Particles Down to 0.003 μm

Advanced electronic air decontamination designed specifically for hospitals, clinics, intensive care units, and cleanrooms. Utilizing patented Genano Technology, these units remove even the smallest airborne impurities, including nanoparticles, viruses, bacteria, and toxic gases, down to 0.003 micrometers (3 nm).

Unlike traditional HEPA filters that only trap particles and can clog over time, Genano's cold plasma electrical precipitation method actively eliminates caught microbes, ensuring a constantly sterile, clog-free airflow with zero risk of secondary emissions.

0.003 μm Nano Capture Cold Plasma Tech Zero Clogging Airflow Filter-Free Design
Genano Nanoparticle Air Purifier
Patented Innovation

Superior Nano-Scale Technology for Air Decontamination

Nano Particle Capture

Removes particulate matter down to nano size (3 nm).

Pathogen Removal

Eliminates viruses, bacteria, and aggressive molds.

Gas & Odour Elimination

Removes toxic chemical gases, VOCs, and clinical odors.

Plug & Play

Easy plug and play implementation for fast setup.

Filter-Free Design

No disposable filters needed, saving ongoing replacement costs.

Easy Maintenance

Automatic self-washing system for effortless upkeep.

Proprietary Patented Technology
Operations in Over 50 Countries
More Than 15,000 Installations
Infection Prevention and Control Guidelines
WHO & CDC Compliant Healthcare Decontamination Standards

“Prevention is better than cure” is a widely recognized proverb that emphasizes the importance of preventing infections to avoid suffering, pain, and financial losses. Infections occur when pathogens like bacteria, viruses, fungi, or parasites invade the body, leading to harm through complex interactions with the immune system.

Organizations like the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC) are at the forefront of formulating guidelines for infection prevention and control. Maintaining pure air and clean surfaces is essential for hygienic environments. Alongside standard hygiene practices, modern technologies play a crucial role in reducing infections and protecting vulnerable populations.

For immunocompromised individuals, extra safety measures are vital to mitigate serious health risks. Innovative technologies such as UVC lights, HEPA and ULPA filters, and ionization are being developed and implemented globally to effectively address these challenges. While traditional manual cleaning methods are prone to human error, identifying high-risk areas and applying consistent, purpose-driven technologies can significantly enhance decontamination efforts.

These advanced technologies improve the safety and habitability of indoor spaces, making them infection-free for everyone.

Clinical Superiority

Advantages of Genano Products

Constant CADR 24x7: Maintains consistent clean air delivery rates continuously without drop-offs.
No Microbe Growth Substrates: Steel precipitation core deprives bacteria of breeding areas.
Does Not Produce Ozone: Certified 100% safe for standard populated patient environments.
Eliminates 99.999% Pathogens: Highly efficient eradication rate for viruses, bacteria, and spores.
Low Lifetime Running Costs: No recurring annual replacement filters to purchase or dispose of.
Saves Time and Money: Significantly reduces hospital facility maintenance downtime.
Complements Existing Ventilation: Integrates smoothly with central HVAC and AHU air systems.
Immediate Effects: Rapid commissioning allows for immediate clinical ward deployments.
No Chemical Residues: Operates completely clean without aerosols, sprays, or synthetic residues.
Safeguards Patients & Staff: Provides ultra-clean medical grade environments for peak safety.
Broad-Spectrum Elimination

What Genano Removes From Air

Viruses
Bacteria
VOC Gases
Odours
DNA Fragments
Prions
Molds & Fungi
Hospital-Wide Versatility

Target Clinical Applications

Patented air decontamination tailored for critical medical environments.

OT / OR
NICU / SICU
IVF Centres
Isolation Wards
Burns Wards
Ophthalmology OTs
Pathology & Labs
Forensic & Autopsy
Pharma Labs
Cancer Wards
Stem Cell Centres
Dental Clinics
Tuberculosis Wards
Transplant Centres
Dynamic Pressure Engineering

Create Positive or Negative Air Pressure with Genano 5250i

Or use it as a standalone plug-&-play decontamination unit in any critical indoor area.

Stand-alone Decontamination Mode Stand-alone Mode
Standalone Circulation & Clean Air
  • Pathogen Barrier: Prevents transmission of infectious airborne microbes within enclosed zones.
  • HAI Prevention: Prevents surgical site infections and Hospital-Acquired Infections (HAIs).
  • Patient Protection: Protects and isolates immunocompromised and vulnerable patients.
  • Hygienic Critical Areas: Raises hospital hygiene levels in critical areas, isolation wards, and protected zones.
Positive Pressure Shield

Creating positive differential pressure prevents external pathogens from entering the room. Highly recommended for protecting vulnerable patients during surgical recovery or high-risk immunological treatments.

Typical Applications: Burns Ward, Organ Transplant Rooms, Stem Cell Rooms, Cancer Wards, Sickle Cell Wards.
Positive Air Pressure Mode Positive Pressure Mode
Negative Air Pressure Mode Negative Pressure Mode
Negative Pressure Isolation

Creating negative differential pressure prevents airborne pathogens from escaping into adjacent hospital corridors and wards. Essential for containing highly contagious infections and preventing epidemic outbreak spread.

Typical Applications: Isolation Wards, Tuberculosis (TB) Wards, COVID Isolation Units, Infectious Disease Quarantine.
Engineering Comparison

Technical Specifications

Tested according to laboratory standard IEC 61010-1. Certified by CE and CB.

Technical Information Genano 350 Genano 5250i
Clean Air Delivery Rate (CADR) 50 – 300 m³/h (Boost mode: 395 m³/h) 100 – 500 m³/h
Particle Cleaning Efficiency > 99% of 0.1 μm particles 99.5% of particles ≥ 0.003 μm (3 nm)
Microbiological Efficacy 99.9% Microbial Elimination 99.999% Microbial Elimination
Gas Adsorption Matrix 600g / 80mm active carbon 1100g / 60mm active carbon
Dimensions (W × H × D) 30 × 90 × 37 cm 60 × 168 × 60 cm
Unit Weight 19 kg 91 kg
Chassis Material Cleanroom Aluminium Aluminium & Painted Medical-Grade Steel
Installation & Mobility Stand-alone with 2 lockable wheels, wall-mountable Stand-alone with 4 lockable wheels, wall-mountable
Fan Speed Control 10-step digital speed control 10-step digital speed control
Power Consumption 10 – 43 W (Boost mode: 180 W) 38 – 137 W
Sound Pressure Level 18 – 44 dB(A) at 3 m (Boost: 58 dB(A)) 24 – 53 dB(A) at 3 m
Rated Voltage 220 – 240 Vac, 50/60 Hz 220 – 240 V, 50/60 Hz
Earth Leakage Current IEC 60601-1 Medical Devices Compliant Standard Clinical Grounding
Operational Temperature Range +5 °C to +40 °C +5 °C to +40 °C
Standard & Optional Accessories Wall bracket, insect screen Negative / Positive pressure duct kit, Insect screen

Breathe Medical-Grade Pure Air with Genano

Contact Cygnus Tech Lab for clinical consultations, airflow turnover calculations, isolation room planning, and institutional quotes.

Enquire Today